Solahart Sunheat

Roof Top Solar System

Solahart Sunheat Series is an Australian designed solar water heater specifically developed to provide hot water free from the sun in medium to high solar gain areas. The black polyester powder-coated aluminium absorber collects the sun’s heat and transfers it to the water in the copper risers. The increase in temperature causes the water to rise and move into the storage tank where it displaces cooler water. This cooler water then travels back into the solar collectors to be heated by the sun. Every system is supplied with Tank, Collector and Hot and Cold pipes.

Capacity

The Solahart Sunheat System is available in 150lt to ensure smaller households have ample hot water.

Mounting Options

With mounting options for flat and pitched roofs; open vented and high pressure, we have a solution for any sitution.

151BPT Roof Top Solar: Key Attributes

OPTIMAL PERFORMANCE

In medium solar gain areas that do not experience frost

Most suitable for areas that receive medium to high levels of solar radiation and are not subject to frost conditions.

CERAMIC LINED TANK

Minimal Maintenance, Maximum Protection

Corrosion protection for the water heater’s solar tank is achieved by using a proven, high quality vitreous enamel lining on the tank. Additional protection is gained by the use of a sacrificial anode.

BOOSTER OPTIONS

All system are supplied with a backup electric booster

The electric boosted models are equipped with an in-tank element. Alternatively the system can be installed as a pre-heater with an inline Solahart gas booster water heater.

Key Features

Solahart Sunheat Series is an Australian designed solar water heater specifically developed to provide hot water free from the sun in medium to high solar gain areas. The black polyester powder-coated aluminium absorber collects the sun’s heat and transfers it to the water in the copper risers. The increase in temperature causes the water to rise and move into the storage tank where it displaces cooler water. This cooler water then travels back into the solar collectors to be heated by the sun.

The tank enamel for enhanced protection, as well as a protective sacrificial anode to improve the life of the tank. The Sunheat Series also utilises Solahart flat plate collector technology. This results in extra-strong glass that is resistant to breaking. Flat plate collectors provide a stronger, safer application when installed on your roof and give greater durability and sustainability than evacuated tubes.

Technical Specifications

Model 151BPT
Tank Model 150RD18 & 150RD00
Storage Capacity 150 litres
Tank Dimensions 1620mm x 510mm x 510mm
System Dimensions Pitched: 1670mm x 2490mm x 1120mm
  With Pitch: 1670mm x 2490mm x 570mm
Heating Unit Copper sheath immersion element
Supply Voltage 220-240V 50-60Hz
Water Connections Cold: Rp 3/4″, Hot: Rp 3/4″
Rated Power 1.8kW
Maximum Water Supply Pressure 800 kPa
TPR Valve Setting 1,000 kPa
BPT20007 Collectors
Aperture (heating) Area 1.87 m2
Dimensions  
Length 1943 mm
Width 1027 mm
Height 83 mm
Capacity 1.2 litres
Weight*  
Empty 29 kg
Full 32 kg
Working Pressure 1000 kPa 
145 psi
Absorber Surface Black polyester powder coat
Absorber Material aluminium
Riser Material copper tube
Tray Material 0.45mm prepainted steel
Insulation Material – Base 38 mm polyester blanket
Glass 3.2 mm tempered low iron glass

* Weight includes fittings

  Pitched Roof Frame Flat Roof Frame
Solahart Thermosiphon Systems Model VN1000005 VN1000002
150L Tank 150RD18 1 1
Collector BPT20007 1 1
TPR Valve SP0262002 Optional Optional
Cold Pipe Sub Assembly VN1000004 1 1
Hot Pipe Sub Assembly VN1000003 1 1

How Roof Top Solar Systems Work

Solar Operation

The Solahart Sunheat solar system has its vitreous enamel lined solar storage tank installed on the roof directly coupled to the solar collectors. It works on the simple scientific fact that hot water rises. As the sun heats the water in the solar collectors, the increase in temperature causes the water to rise through an insulated copper pipe into the storage tank. This allows cooler water from the solar storage tank to flow into the solar collectors to be heated by the sun’s energy. This process continues while solar energy is available.

Orientation of Solar Collectors

To help maximise system performance, solar collectors should be installed with an optimum orientation facing true north (in the southern hemisphere) or true south (in the northern hemisphere). Always check for true north or true south using a compass or other suitable device.

To help maximise system performance, solar collectors should be installed with an optimum inclination. This is equal to 90% to 100% of the local latitude angle when collectors are oriented within 60° of true north or true south, and between 10° and 20° if the collectors are oriented between 60° and 90° from the optimum orientation. Generally, improved summer performance is obtained from an angle of inclination less than the optimum angle and improved winter performance is obtained by an angle of inclination greater than the optimum angle. If the angle of inclination varies by 20° from the optimum angle, the solar collectors will receive about 10% less total annual solar radiation.

Frost/Freeze Protection

An Open Circuit system does not have freeze protection and is not suitable for installation in areas prone to freeze conditions. Freeze conditions occur below 5°C (41°F). This system has NO WARRANTY for freeze damage. In areas that are prone to frost / freezing, a Closed Circuit system should be used.

Solar Boosting

An isolating switch is installed in the electrical meter box for an electrically in-tank boosted model. This should be left switched on to allow the booster heating unit to operate if required. The booster heating unit is for heating the water at times of low solar energy gain, such as during very cloudy or rainy weather, or during the colder months. The booster heating unit will only activate if heating is required and power is available from the switchboard. When the water is below the thermostat setting, the booster heating unit will turn on and heat the water. The booster heating unit will automatically turn off when the temperature of the water reaches the thermostat setting. If the water temperature drops below the setting again the booster will re-activate.

Downloads

Why Solahart Solar Hot Water Systems: Download

Solahart Sunheat Solar Hot Water System Brochure: Download

Solahart On-Roof Solar Hot Water System Owner’s Guide and Installation Manual: Download